5-Hap Hematology Analyzer Calibrator

5-Hap Hematology Analyzer Calibrator

5-Part Hematology Analyzer Calibrator em i wanpela stebol, multi-paramita refrens materiel we ol i wokim wantaim ol 'preserved biological cellular components' bilong stretim na sekim stretpela bilong skelim bilong ol 'automated differential cell counters'. Em i save givim gutpela 'target value' asainmen long olgeta 'blood count' na 'white blood cell differential parameters', na dispela i mekim na ol i ken bihainim stret ol 'metrological traceability' long ol intanesenel standet refrens rot.

Prodak Introdaksen

5-Part Hematology Analyzer Calibrator em i wanpela stebol, multi-paramita refrens materiel we ol i wokim wantaim ol 'preserved biological cellular components' bilong stretim na sekim stretpela bilong skelim bilong ol 'automated differential cell counters'. Em i save givim gutpela 'target value' asainmen long olgeta 'blood count' na 'white blood cell differential parameters', na dispela i mekim na ol i ken bihainim stret ol 'metrological traceability' long ol intanesenel standet refrens rot.

 

Wanem samting em ol 'hematology controls' / 'calibrators'?

 

Long klinikel leboretori daignostiks, ol kalibreta na ol kontrol i save mekim ol narapela narapela wok bilong lukluk long en:

Ol kalibretamakim matematikel rilesensip namel long ol instramen sensa signal na ol trupela fisikel sel konsentresen, na kamapim namba wan mesamen beslain.

Ol kontrollukluk long ol wok painimaut we i save kamap long olgeta de na sistem i stap gut longpela taim, na sekim sapos ol skelim i stap insait long mak bilong standet deviesen na noken senisim ol seting bilong sistem.

 

Rol long Hematology Kwaliti Kontrol

 

Stretpela kalibresen i givim as mak bilong kaunim ol sel bilong blut:

Sistem Rekalibresen:Re-i kamapim stretpela wok bilong skelim ol samting bihain long ol i mekim bikpela wok bilong lukautim wara, stretim gen ol samting bilong lukluk, o senisim ol samting bilong en.

Reagent Lot Transition:I stretim ol senis long 'baseline' taim yu senisim namel long ol 'production lots' bilong 'diluent', 'lyse', o 'cleaning solutions'.

Metrological Traceability:I linkim ol wok bilong skelim ol samting long laboratori long olgeta de i go stret long ol standet praimeri refrens rot aninit long ISO 17511 gaidens.

Stretim Sif:I stretim ol 'systematic calibration drift' we ol i painim long taim bilong 'statistical quality control monitoring' long olgeta de.

 

Kontrol Level / Aplikesen

 

Taim ol 'calibrator' i makim 'central analytical accuracy', ol 'companion quality controls' i save sekim wok bilong ol long ol narapela narapela 'operational ranges':
Low Level
Monita sensitiviti bilong ditekta na low-end linearity, em i bikpela samting long skelim ol klinikel sempel wantaim bikpela sik 'leukopenia', 'thrombocytopenia', o 'anemia'.
Nomal Level
Em i sekim ol wok painimaut insait long ol standet 'physiological ranges' bilong ol helti refrens populesen, na i stap olsem mak bilong wok long olgeta de.
Hai Level
Skelim 'system linearity' na 'optical performance' long ol bikpela sel konsentresen, na mekim stretpela skelim long taim bilong bikpela 'leukocytosis' o 'thrombocytosis' kondisen.

 

Kontrol na Kalibreta

 

Pasin

Kalibreta

Kontrol

Namba wan As tingting

Stretim ol instramen kalkulesen fakta na ditekta sensitiviti

Lukautim stretpela wok bilong skelim na wok i go het

Planti taim bilong yusim

Periodik (instolesen, mentenens, senisim lot, drif)

Long olgeta de o long olgeta operesenel tes ran

Value Assignment

Ol i stretim ol mak we ol i makim long rot bilong ol standet refrens rot

Ol mak we ol i makim pinis wantaim ol mak bilong senis we i orait

Sistem Eksen

I apdetim ol intanel gain fakta na ol kalibresen koefisen

Konfemim olsem instramen i redi o makim ol asua long wok

 

Ol masin bilong skelim blut we i stret wantaim

 

Ol i wokim bilong opim na pasim ol 'sampling channels' long ol 'optical scatter', 'electrical impedance', na 'colorimetric' mesamen teknoloji:

  • Ol 'differential analyzer' we i yusim 'semiconductor laser scatter' na 'flow cytometry'
  • Ol sistem bilong kaunim ol 'impedance cell' we i yusim 'hydrodynamic focusing'
  • Cyanide-free hemoglobin colorimetric measurement modules

 

Ol veliu / parameta we ol i makim

 

Paramita

Sotpela nem

Tipikel Assigned Taget Value

Yunit

Kaun bilong ol retpela sel bilong blut

RBC

4.50 ± 0.15

10¹²/L

Hemoglobin Konsentresen

HGB

135 ± 3

g/L

Hematocrit

HCT

40.0 ± 1.5

%

Min Korpuskula Volium

MCV

88.0 ± 2.0

fL

Namba bilong ol waitpela sel bilong blut

WBC

7.50 ± 0.30

10⁹/L

Pesen bilong ol 'neutrophil'

NEUT%

60.0 ± 3.0

%

Limfosait Pesen

LYMPH%

28.0 ± 2.5

%

Monocyte Percentage

MONO%

6.0 ± 1.5

%

Pesen bilong Eosinofil

EO%

4.0 ± 1.0

%

Basophil Percentage

BASO%

2.0 ± 0.8

%

Namba bilong ol pletlet

PLT

240 ± 15

10⁹/L

 

Ol spesifikasen bilong prodak

 

Samting

Teknikel Spesifikesen

Stet bilong bodi

Redi-long-yusim wara i hangamap

Matriks Komponen

Ol 'biological cell suspensions' we ol i bin lukautim gut

Pulimapim volium

3.0 mL long wan wan botel

Traceability Standard

ISO 17511 bihainim ol refrens rot

Ol Konfigurasen bilong Pakejing

2 x 3.0 mL / 4 x 3.0 mL / Ol OEM bikpela paket we ol i wokim long laik bilong ol yet

 

Stoa na Stebiliti

 

Tempereja bilong putim:Putim stret namel long 2 digri na 8 digri. Lukautim long ais na lait stret.
Laip bilong Shelf we i no op yet:105 de stat long de bilong wokim taim ol i putim long 2 digri i go inap 8 digri.
Open-Vial Stability:7 de aninit long strongpela aseptik hanling na kwiktaim go bek long 2 digri i go long 8 digri stoa bihain long kisim sempel.
Thermal Logistics:Ol i salim wantaim ol kol kontena we i gat tempereja-monitoring na i stap namel long 2 digri na 8 digri.

 

Kwaliti Asurens

 

Reference Method Alignment:Ol veliu we ol i makim long yusim ol 'standardized microscopic reference methods' na ol 'verified master reference instruments'.
Homogeneity Control:Olgeta lot i save go insait long 'vial-to-vial consistency testing na 'coefficient of variation verification' pastaim long ol i rilisim.
Manufakturing Kompliens:Ol i wokim aninit long ISO 13485 kwaliti menesmen sistem bilong ol 'diagnostic medical devices'.
Sefti bilong ol samting i stap laip:Ol samting we ol i bin testim i no -reactive long HBsAg, anti-HCV, na anti-HIV antibodi.

 

FAQ

 

Q: Wanem taim ol i mas mekim 'calibration'?

A: Kalibresen i mas kamap taim ol i putim instramen pastaim, bihain long bikpela optikal o fluid mentenens, taim ol i senisim ol 'reagent lots' we i soim 'systematic drift', o taim ol 'deili quality control' risal i save pundaun ausait long ol mak bilong kontrol.

Q: Dispela kalibreta i ken wok wantaim 'open' na 'closed vial aspiration'?

A: Yes, ol i wokim 'fluid suspension' bilong holim wankain 'viscosity' na 'cellular distribution' long tupela 'manual open-vial modes' na 'automated closed-vial sampling systems.

Q: Olsem wanem ol i save kamapim ol 'target values' bilong wanwan 'parameter'?

A: Ol i makim ol veliu bihainim ISO 17511 'metrological traceability guidelines', na yusim ol 'reference measurement procedures' na ol 'standardized master analyzers'.

Q: Wanem ol samting yu mas redim pastaim long kisim ol sempel?

A: Tanim botol isi isi long han planti taim long mekim gutpela 'suspension'. Noken seksekim hariap long stopim fom o 'micro-bubble entrapment we inap long bagarapim ol 'optical scatter readings'.

Q: Olsem wanem ol i save lukautim gut ol samting long taim bilong salim ol samting i go long ol narapela kantri?

A: Ol sipmen i save yusim ol kontena we i gat insulet na i gat ol 'cold pack' na ol 'internal temperature monitors' bilong holim 2 digri i go inap 8 digri envairomen long olgeta taim bilong trensit.

Hot Tag: 5-pat hematoloji analisa kalibreta, Saina 5-pat hematoloji analisa kalibreta manifakta, saplaia